How the rebar count works
- Subtract the edge clearance from each side. With 3 in clearance, a 12 ft slab gives a bar run of 12 − 2 × 0.25 = 11.5 ft.
- Count the bars across each direction: run in inches ÷ spacing, rounded down, plus 1 for the bar at the far edge. 11.5 × 12 = 138 in; 138 ÷ 18 = 7.67, so 7 + 1 = 8 bars.
- Bars running lengthwise are spaced across the width, and bars running crosswise are spaced along the length. Each bar is as long as its run.
- Cut the runs from stock bars. If a run fits in one stock bar, the calculator fits as many runs per bar as it can. If a run is longer than a stock bar, it is made of pieces joined by laps, and each lap adds its length to the steel you buy.
- Weight = total linear feet with laps × lb per foot for the bar size.
| Bar size | Nominal diameter | Weight per foot (ASTM A615) | Default lap (40 × diameter) |
|---|---|---|---|
| #3 | 0.375 in | 0.376 lb/ft | 15 in |
| #4 | 0.500 in | 0.668 lb/ft | 20 in |
| #5 | 0.625 in | 1.043 lb/ft | 25 in |
The lap field is an editable default, not a code minimum. Leave it blank to use 40 × the bar diameter, or type the lap length from your plans or local code.
Worked examples
12 × 12 ft slab, #4 at 18 in, 3 in clearance, 20 ft stock. Each run is 11.5 ft, so there are 8 bars each way and 184 linear ft. No laps are needed. Only one 11.5 ft run fits in a 20 ft bar, so you buy 16 stock bars, 122.9 lb.
24 × 20 ft slab, #4 at 12 in, 3 in clearance, 20 ft stock, 20 in lap. There are 20 lengthwise bars of 23.5 ft, each made of two pieces with one lap, and 24 crosswise bars of 19.5 ft. That's 938 ft without laps and 971.33 ft with laps, 51 stock bars and 648.9 lb. With 10 ft stock, the same slab needs 1,084.67 ft, 116 bars and 724.6 lb, because every run needs two laps.
10 × 10 ft slab, #3 at 18 in, 3 in clearance, 10 ft stock. Each run is 9.5 ft, so there are 7 bars each way and 133 ft. You buy 14 stock bars, 50.0 lb.
Spacing and placement
Spacing comes from the plans. One example: the City of Brea's residential foundation requirements say to "provide 5” slab on grade reinforced with #4 at 18” on centers each way". Other jurisdictions and designs differ. For the cover below the bars, the Wire Reinforcement Institute (TF 702-R-21) says "many who design floors consider 1 1/2” of clear cover below the steel to be adequate", unless the governing code requires more, up to 3 in. Where the steel sits in the depth of the slab, and whether to use welded wire mesh instead, is covered in rebar vs wire mesh for a concrete slab. For the concrete itself, use the concrete slab calculator.
Frequently asked questions
How much does #4 rebar weigh per foot?
ASTM A615 lists #4 bar at 0.668 lb per foot, with a nominal diameter of 0.500 in. #3 bar is 0.376 lb/ft and #5 bar is 1.043 lb/ft. A 20 ft #4 bar weighs about 13.4 lb.
How many 20 ft bars of rebar do I need for a 20×20 slab?
At #4 bar, 12 in on center each way and 3 in edge clearance, each run is 19.5 ft, so a 20 ft bar covers it with no laps. That's 20 bars each way, 40 stock bars, 780 linear ft and about 521 lb, before any extra for waste.
How long should a rebar lap splice be?
An old rule of thumb is 40 bar diameters, which is 20 in for #4 bar. Pool & Spa News notes the same rule of thumb used 60 diameters for grade 60 steel, and that engineers now recommend following their specifications or the ACI 318 equation. CRSI says the ACI 318 Building Code requires the engineer to indicate locations and lengths of all lap splices on the structural drawings. Use the lap from your plans or local code; the 40-diameter default here is only a starting point.
How far from the edge of the slab should rebar stop?
The calculator uses 3 in by default. ACI 318 Table 20.6.1.3.1 specifies 3 in of cover for concrete cast against and permanently in contact with ground. Your plans may give a different edge or bottom cover, so enter what they show.
Should I buy 10 ft or 20 ft rebar?
Longer bars mean fewer laps. For the 24 × 20 ft example, 20 ft stock needs 971.33 ft and 51 bars, while 10 ft stock needs 1,084.67 ft and 116 bars, because every run needs extra laps. 10 ft bars are easier to carry, but they add steel and tying.
Does the calculator include waste?
No. The stock bar count is exactly what the layout needs, with no waste allowance. Add a few extra bars, for example 5%, for cutting mistakes and bent ends.
Sources
- ASTM A615/A615M-13, Table 1: deformed bar unit weights and nominal diameters (MegaStd preview)
- InterMetal rebar bar chart (A615 weights: #3 0.376, #4 0.668, #5 1.043 lb/ft)
- City of Brea: Foundation Requirements for Residential Projects and Accessory Structures
- ACI 318 Table 20.6.1.3.1 concrete cover, reproduced by Callout
- Wire Reinforcement Institute TF 702-R-21, Slab on Grade
- Pool & Spa News: A lap for durability (40 and 60 bar-diameter rules of thumb)
- CRSI: Lap splices