MyProjectCalcs

How Deep Should Deck Footings Be? (Frost Line & Code)

By Vinod Kondeti · Published

Deck footings must sit at least 12 inches below undisturbed soil, or below your local frost line, whichever is deeper. That’s the rule in the International Residential Code (Section R403.1.4 and its frost-protection subsection), and the American Wood Council’s deck guide, DCA 6, repeats it for deck footings. The frost line changes from place to place, so there is no single depth that is right everywhere. Your building department sets the actual depth for your address, and it may have local amendments that go deeper than the model code.

The rest of this post explains why frost matters, the extra rule for footings near the house, how big DCA 6 makes the footings, how much frost depths vary between states, and how much concrete a set of deck footings takes at two different depths. Once you know your depth and footing size, the concrete footing calculator turns them into yards and bags.

What the code actually says

Two IRC sections work together. As the City of Boise quotes them in its building policy:

  • R403.1.4 Minimum depth: “Exterior footings shall be placed not less than 12 inches below the undisturbed ground surface.” Where it applies, the depth must also meet the frost-protection section.
  • R403.1.4.1 Frost protection: permanent supports, including piers, must be protected from frost, most often by extending them below the frost line given in the code’s climate table (Table R301.2(1)). Other allowed methods are a frost-protected shallow foundation, a design to ASCE 32, or bearing on solid rock. And footings “shall not bear on frozen soil unless the frozen condition is permanent.”

DCA 6 puts the same two rules into one sentence for decks: “All footings shall bear on undisturbed soil at least 12 inches below the undisturbed ground surface or below the frost line, whichever is deeper.” It then tells you to “contact the authority having jurisdiction to determine the specified frost line.”

Two words in that sentence matter as much as the number:

  • Undisturbed soil means ground that hasn’t been dug up and backfilled. A hole that was overdug and then partly refilled with loose dirt doesn’t qualify. Measure from the undisturbed ground surface, not from the top of new topsoil or fill.
  • Frost line is set locally. The code’s own table leaves the value for each jurisdiction to fill in, which is why DCA 6 sends you to the building department rather than printing a depth.

Why footings go below the frost line

When wet soil freezes, it expands. Penn State’s Pennsylvania Housing Research Center puts it simply: the base of a foundation “must extend below the regionally specific frost depth in order to prevent the earth below the foundation from heaving. Heaving occurs when moisture present in soil freezes and expands, thus exerting differential forces on structural components above the soil.”

“Differential” is the key word for a deck. If one footing lifts and its neighbor doesn’t, the beam racks, the ledger connection at the house takes load it wasn’t built for, and the deck surface goes out of level. A footing whose bottom is below the frost line bears on soil that doesn’t freeze, so it has nothing pushing up from underneath.

Depth alone doesn’t solve everything. A National Research Council Canada building digest on frost heave notes that placing footings below the frost line in frost-susceptible soil “does not necessarily ensure” protection, because frozen soil can grip the sides of a post or pier and lift it. That process is called adfreezing. The digest describes ways to deal with it, such as a drained zone of gravel around the column or anchoring the column to a footing below the frost. It also notes that the more slender the column within the frozen layer, the smaller the uplift force. This is one reason a narrow tube on a wider footing, the arrangement DCA 6 shows, is common. If you build where frost runs deep, ask your building department whether it has a local detail.

Footings within 5 ft of the house

DCA 6 adds a rule that catches many deck builders: footings closer than 5 ft to an exterior foundation wall of the house must bear at the same elevation as the bottom of the house footing. The soil next to a basement or crawlspace wall was dug out and backfilled when the house was built, so it is disturbed soil, often deeper than the frost line. A deck footing set in that backfill can settle.

In practice, a footing for a beam that sits close to the house can need to go much deeper than the footings farther out, sometimes down to basement-footing depth. For houses with basements, DCA 6 recommends a cylindrical footing (a caisson) to keep the excavation next to the basement wall small. DCA 6 also reminds you to call 811 before digging so buried utilities are marked.

How big the footing has to be

Depth gets the footing below frost. Width spreads the deck’s load over enough soil. DCA 6 Table 4 sizes footings from two numbers on your plan: the beam span and the joist span. Its assumptions are 1,500 psf soil bearing capacity and 2,500 psi concrete (the minimum values from the IRC tables, according to the DCA 6 commentary), and the sizes are for center posts. A footnote lets you multiply the dimensions by 0.9 for corner posts, which carry less.

Beam span Joist span up to Round footing diameter Square footing Thickness
6 ft 10 ft 18 in 16 × 16 in 7 in
6 ft 14 ft 21 in 18 × 18 in 8 in
6 ft 18 ft 24 in 21 × 21 in 10 in
8 ft 10 ft 20 in 18 × 18 in 8 in
10 ft 10 ft 23 in 20 × 20 in 9 in
18 ft 18 ft 42 in 37 × 37 in 19 in

These rows are a sample. The full table covers beam spans from 6 to 18 ft and joist spans up to 18 ft, so use it, or your building department’s own handout, for your deck. The smallest round footing in the table is 18 in across, the largest 42 in.

DCA 6’s commentary shows options that combine a footing with a narrower concrete stem, including a 12 in diameter concrete stem on a footing, which the commentary says was added “to reduce the amount of concrete required.” The stem is usually poured in a tube form. For tube sizing and bag counts, see what size sonotube for a 6x6 post and the sonotube concrete calculator.

How frost depth varies: three state examples

These figures come straight from state codes and a city building policy. They show how much the answer changes with location. They are not a national table, and your own jurisdiction can differ from its neighbors.

  • Minnesota. The state rule on minimum footing depth (Minnesota Rules 1303.1600) sets the minimum footing depth “due to freezing” at 5 ft in Zone I and 3 1/2 ft in Zone II, unless a soils engineer shows that less is fine. Zone I is the northern counties, such as St. Louis, Beltrami and Otter Tail. Zone II is the southern ones, including Hennepin, Ramsey and Dakota.
  • Wisconsin. The Uniform Dwelling Code (SPS 321.16) says footings and foundations “shall be placed below the frost penetration level or at least 48 inches below adjacent grade, whichever is deeper.” SPS 321.15 applies the footing rules to the dwelling “and attached structures, such as decks and garages.” The code allows a few exceptions, including footings bearing directly on bedrock under set conditions.
  • Boise, Idaho. The city’s building policy for small storage buildings refers to the local 24-inch frost depth requirement.

So depending on where you live, a code-compliant deck footing might bottom out at 24 in, 42 in, 48 in or 60 in, and possibly deeper near the house. Even within one state the number changes with zone and soil. That is why no national depth appears in this post.

Free-standing decks

The model IRC text that Boise quotes includes an exception: “Decks not supported by a dwelling need not be provided with footings that extend below the frost line.” Not every state keeps it. Minnesota’s current amendment of R403.1.4.1 (Minnesota Rules 1309.0403) doesn’t list that exception. Even where it applies, the 12 in minimum below undisturbed ground still holds. Check with your building department before you count on it.

Worked example: concrete for six deck footings at two depths

Here is the concrete for a small deck with six footings, each a 16 × 16 in square footing, 7 in thick, the size in DCA 6 Table 4’s first row. Each footing carries a 12 in round tube stem up to grade. The comparison uses two of the frost depths above: the bottom of the footing at 42 in (3 1/2 ft) and at 60 in (5 ft). Every number comes from the site’s calculator code. Bag yields are 0.60 ft³ per 80 lb bag and 0.45 ft³ per 60 lb bag, from QUIKRETE’s Concrete Mix data sheet.

The footings (same at both depths):

  • One footing: 16 × 16 in × 7 in = 1.04 ft³.
  • Six footings: 6.22 ft³. In the footing calculator, enter a length of 1.333 ft (16 in), a width of 16 in, a depth of 7 in and a quantity of 6.

The tubes. Each tube runs from the top of the footing to grade, so its height is the footing depth minus the 7 in footing.

Footing bottom at 42 in Footing bottom at 60 in
Tube height 35 in (2.92 ft) 53 in (4.42 ft)
Six 12 in tubes 13.74 ft³ 20.81 ft³
Six footings 6.22 ft³ 6.22 ft³
Total you need 19.97 ft³ (0.74 yd³) 27.04 ft³ (1.00 yd³)
Need, 80 lb bags 34 46
Need, 60 lb bags 45 61
Buy with 10% extra 21.96 ft³: 37 × 80 lb or 49 × 60 lb 29.74 ft³: 50 × 80 lb or 67 × 60 lb

The extra 18 inches of depth adds about 7 ft³ to the job, roughly a third more concrete, even though the footings themselves are the same size. The footing alone is less than a third of the total at either depth; most of the concrete goes into the stems.

Those totals assume you mix everything as one batch count. If you mix one footing at a time, round per footing. With 10% extra, one 12 in tube needs 5 × 80 lb bags at the 42 in depth and 7 × 80 lb at 60 in, and each 16 × 16 × 7 in footing needs 2 × 80 lb. Rounding per hole can mean a few more bags than the batch total. If you stop partway through a single footing, QUIKRETE warns that partial-depth fills can lead to cold joints. Have enough mix on hand to finish each footing in one pour.

If your top of tube stands above grade, add that height to the tube. For a round footing instead of a square one, use the concrete column calculator with the diameter and thickness.

Before you pour

  • Get the permit and the depth in writing. Your building department will tell you the frost depth and any local footing rules. DCA 6 says bearing conditions “shall be verified in the field by the building official prior to placement of concrete,” so expect an inspection of the open holes before you pour.
  • Dig to undisturbed soil and remove loose dirt from the bottom. Don’t backfill an overdug hole with loose soil to bring it up.
  • Don’t pour on frozen ground. The IRC frost section says footings must not bear on frozen soil unless the frozen condition is permanent.
  • Check the 5 ft zone around the house before you lay out the beam line, so you know which footings must go to house-footing depth.
  • Call 811 before you dig.

Frequently asked questions

Is 36 inches deep enough for deck footings?

Only if 36 in meets your local frost depth and the 12 in minimum below undisturbed ground. In the examples above, it would be too shallow in Wisconsin (48 in) and in both Minnesota zones (3 1/2 and 5 ft). Ask your building department for the number where you live.

Do free-standing decks need footings below the frost line?

The model IRC has an exception for decks not supported by a dwelling, but states can drop it. Minnesota’s current amendment doesn’t list it. The 12 in minimum below undisturbed ground still applies, so check locally.

Why do footings near the house have to be deeper?

DCA 6 requires footings within 5 ft of the house foundation to bear at the same level as the house footing, because the soil next to the foundation was dug and backfilled during construction.

Can I pour a deck footing on frozen ground?

No. The IRC frost-protection section says footings must not bear on frozen soil unless the frozen condition is permanent.

Does the inspector need to see the holes before I pour?

Under DCA 6, yes: the building official verifies bearing conditions in the field before concrete is placed. Schedule the inspection with your building department before you order or mix concrete.

What if I hit rock before the frost line?

Bearing on solid rock is one of the IRC’s listed frost-protection methods. Wisconsin’s code sets specific conditions for footings on bedrock above 48 in, such as cleaning the rock and removing clay from crevices. Your inspector will decide whether your rock qualifies.

How wide should a deck footing be?

That depends on your beam and joist spans. DCA 6 Table 4 runs from an 18 in round (or 16 × 16 in square, 7 in thick) footing for the smallest decks up to 42 in round for the largest, assuming 1,500 psf soil.

Sources

Tags: concrete, decks, footings, frost-depth

← All posts